WoodCalc Pro

1/12 Roof Pitch

A 1 in 12 roof rises 1″ for every 12″ of horizontal run. Flat-looking roofs, porch and patio covers, membrane roofing.

Angle

4.76°

Percent grade
8.3%
Rafter factor
1.0035
Rafter per foot of run
12.04″
Hip/valley per foot
17″
Plumb cut
4.8°
Seat cut
85.2°

On a speed square, pivot to 1 on the "common" scale for the plumb cut. On a framing square, set 1″ on the tongue and 12″ on the body.

run 12″rise 1″4.8°

Low slope: easy to walk on. Roofers price it as standard work.

1/12 rafter length by building span

Gable roof, 1½″ ridge board, measured along the top edge from the ridge to the outside of the wall. Add the overhang: 12 1/16" of rafter per foot of level overhang.

Building spanRafter runRiseRafter lengthWith 12″ overhang
12 ft5′ 11 1/4"5 15/16"5′ 11 1/2"6′ 11 9/16"
16 ft7′ 11 1/4"7 15/16"7′ 11 9/16"8′ 11 5/8"
20 ft9′ 11 1/4"9 15/16"9′ 11 11/16"10′ 11 11/16"
24 ft11′ 11 1/4"11 15/16"11′ 11 3/4"12′ 11 13/16"
28 ft13′ 11 1/4"1′ 1 15/16"13′ 11 13/16"14′ 11 7/8"
30 ft14′ 11 1/4"1′ 2 15/16"14′ 11 7/8"15′ 11 15/16"
32 ft15′ 11 1/4"1′ 3 15/16"15′ 11 15/16"16′ 11 15/16"
36 ft17′ 11 1/4"1′ 5 15/16"18′ 0"19′ 1/16"
40 ft19′ 11 1/4"1′ 7 15/16"20′ 1/16"21′ 1/8"

Different span, ridge or overhang? The rafter calculator works out the birdsmouth, HAP and ridge height for your roof.

Roof area at 1/12

1,349 sq ft · 13.5 squares · 47 sheets of 4×8 sheathing (10% waste)

Roofing materials allowed at 1/12

  • Asphalt shingles
    Not allowed below 2/12 (R905.2.2).
  • Clay and concrete tile
    Not allowed below 2½/12 (R905.3.2).
  • Wood shingles
    Not allowed below 3/12 (R905.7.2).
  • Wood shakes
    Not allowed below 3/12 (R905.8.2).
  • Slate
    Not allowed below 4/12 (R905.6.2).
  • Metal panels, lapped without sealant
    Below 3/12 use standing-seam (¼/12) or lapped panels with sealant (½/12) (R905.10.2).
  • Low-slope membrane (EPDM, TPO, modified bitumen)
    The usual choice at this slope; minimum ¼/12 for drainage.

Minimum slopes from the 2021 International Residential Code, Section R905. Manufacturers and local amendments can be stricter.

Compare other pitches

Questions people ask

What angle is a 1/12 roof pitch?
A 1/12 roof rises 1 inches for every 12 inches of horizontal run, which is 4.76° (arctan(1/12)). As a percent grade it is 8.3%.
What is the rafter factor for a 1/12 pitch?
1.0035. Multiply the horizontal run by 1.0035 to get the sloped rafter length, or multiply the building footprint (with overhangs) by it to get the roof area. Each foot of run needs 12.04" of rafter.
How long is a rafter on a 1/12 roof?
For a 24 ft wide building with a 1½" ridge board, the run is 143.25", so the rafter is 11′ 11 3/4" from ridge to wall line, before the overhang. The table on this page gives lengths for other spans, and the rafter calculator handles your exact numbers including birdsmouth and tail.
Can you put shingles on a 1/12 roof?
Not allowed below 2/12 (R905.2.2). Always follow the shingle manufacturer's installation instructions as well.
Is a 1/12 roof walkable?
Low slope: easy to walk on. Roofers price it as standard work.
How much roof area does a 1/12 pitch add?
0.3% more than the flat footprint. A 30 × 40 ft house with 1 ft overhangs (32 × 42 = 1,344 sq ft) has about 1,349 sq ft of roof, or 13.5 roofing squares before waste.